Technical data sheet COMBIDIC®-2K-CLASSIC 2 component bituminous thick layer coating (PMBC)
Material number
Contents
Unit of quantity
Packaging
Colour
204912002
30
L
Combination packs
Black
Product features Waterproofing material in accordance with DIN 18533, DIN EN 15814 Seam-free and jointless Flexible and crack bridging Polystyrene filled
Advantages Good slump resistance easy and economical application Hand and machine application Radon tight
Fields of application / waterproofing For waterproofing building components in direct ground contact with ground moisture and non pressure water ( W1.1-E, W1.2-E in accordance with DIN 18533) for waterproofing pressing water (W2.1-E in accordance with DIN 18533) For waterproofing against splash water and ground moisture at the wall base (W4-E in accordance with DIN 18533) As retroactive building waterproofing in accordance with WTA datasheet 4-6 As an adhesive for insulation, protection and drainage boards
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 1/6
10/03/2025
Technical data sheet COMBIDIC®-2K-CLASSIC Technical Data Material properties Product components Base material Consistency Density, ready to use product (ISO 1183-1) Crack bridging DIN EN 15812 Crack-bridging ability (classification DIN EN 15814) Rain resistance in accordance with DIN EN 15816 (classification) Watertightness DIN EN 15820 (slotted disc pressure 1mm) Watertightness (classification DIN EN 15814) Watertightness (PG FBB) Compressive strength in accordance with DIN EN 15814 Compressive strength in accordance with DIN EN 15815 Sealing against pressing water until Vapour diffusion behaviour Classification of the reaction to fire in accordance with DIN EN 13501-1
2 component system Polystyrene filled, anionic bituminous thick layer coating Filler consistency approx. 0.7 kg/dm³ > 2 mm CB 2 < 8 hours (R2) >0.75 bar (W2A) W2A 0.5 mm (joint width) C2A 0.3 MN/m² 0.75 bar Vapour diffusion blocking E
Mixing Mixing time
approx. 3 minutes
Application Substrate/application temperature Pot life Consumption pro m² and mm layer thickness
approx. 5 - 30 °C approx. 60 minutes approx. 1.3 l
Material rate Material consumption rate according to the area of application
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 2/6
Technical data sheet COMBIDIC®-2K-CLASSIC Processing equipment Aids/tools Stirrer (approx. 500-700 rpm) Suitable mixing paddle Serrated or layer-thickness trowel Trowel Flat trowel Spray equipment
Manual processing Can be trowelled off
Machine application COMBIDIC®-2K-CLASSIC can be mechanically applied. For precise information, see the additional Technical Information No. 43.
Suitable substrate Building components in direct ground contact
Preparing the substrate Requirement for substrate 1. Frost-free 2. Load-bearing 3. Even 4. Pore open 5. Sealed in the surface 6. Free of adhesion inhibiting substances
Preparing the details 1. Edges are to be chamfered and corners are to be rounded. 2. Depressions > 5 mm and mortar pockets, plaster grooves in brickwork, open butt or bed joints, damaged areas, large pored substrates or uneven masonry work must be levelled in advance with ASOCRET-M30.
Wall/floor transitions, internal corners, joints 1. Pre-screen the professionally prepared substrate with AQUAFIN-1K or ASOCRET-M30 featuring consistency that can be screened, and install a sealing cove of ASOCRET-M30 with an edge height of at least 4 cm while it is still wet. 2. In the area of structural movement joints, the waterproofing is reinforced with ADF-Dehnfugenband (Expansion-Joint-Tape) or ASO-Joint-Tape2000-S and integrated in the area waterproofing.
Intersections 1. Intersections must be connected to the pipes or casing pipes by means of sealing coves. Alternatively, depending on the nominal diameter, ASOJoint-Sleeve-Floor, ASO-Joint-Sleeve-Wall or ADF-Pipe-Gasket can be used. 2. In the water exposure class W2.1-E and W3-E, intersections with suitable adhesive or loose / fixed flange constructions are to be used and integrated into the area waterproofing. 3. The following area is to be waterproofed and must be carried out at least 5 cm onto the pipe penetration. 4. In accordance with the specifications of DIN 18533, an increased dry film thickness of 5 mm must be applied in the area of the flange constructions. The use of spacers must ensure that the layer thickness does not fall below 4 mm after the loose flange has been clamped.
Splash water zone / plinth area 1. In the area of the splash water zone, the waterproofing must be run a minimum 30 cm above the ground. 2. After being adjusted to the ground, the waterproofing must reach ≥ 15 cm above ground level. 3. As standard, this connection is established with flexible, cementitious waterproofing slurry, e.g. AQUAFIN-RB400, in order to achieve an adhesive substrate, e.g. for building skirt renders, etc. 4. The overlapping of the bituminous thick layer coating on the waterproofing slurry is min. 10 cm here
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 3/6
Technical data sheet COMBIDIC®-2K-CLASSIC Application Mixing 1. Stir the bitumen component briefly with a stirrer. 2. Completely add the powder to the bitumen component and mix until homogeneous and free from lumps. 3. The mixing time is ca. 3 minutes.
Application 1. Prepare the substrate with a primer coat of ASOL-FE (diluted 1:5 with water). 2. In the case of very absorbent concrete substrates, a scratch coat is recommended to avoid the formation of air bubbles in the bituminous thick layer coating. 3. After complete drying of the primer / scratch coat, COMBIDIC®-2K-CLASSIC can be applied.
Water exposure class W1.1-E and W1.2-E 1. Apply COMBIDIC®-2K-CLASSIC with a flat trowel in min. 2 application steps. 2. A fully covering scratch coat can be applied as the first layer. 3. To achieve an even layer thickness, ideally comb with a toothed trowel or coating thickness trowel of the appropriate size and form a sealed surface with the smooth side of the toothed trowel. 4. Application takes place while the product is still wet. 5. In the area of the base slab, the waterproofing must be run at least 10 cm down the end face of the sill.
Water exposure class W2.1-E and W3-E 1. Apply COMBIDIC®-2K-CLASSIC with a flat trowel in min. 2 application steps. 2. The ASO® reinforcing fabric is to be installed on the fresh first waterproofing layer. 3. Before applying the second layer, the first layer must have dried sufficiently to exclude damage by the following layer. 4. In the area of the base slab, the waterproofing in water exposure class W2.1. must be run at least 15 cm down the end face of the sill.
Testing the waterproofing A layer thickness check should always be carried out and documented. The layer thickness check is carried out in the fresh condition by measuring the wet film thickness (at least 20 measurements per building project or at least 20 measurements per 100 m²). Drying / the dry film thickness is destructively tested using the wedge cut method on a reference sample consisting of the project substrate stored in the building pit.
Back-filling of the building pit: Back-filling the building pit can take place after the bituminous thick layer coating is totally dry.
Cleaning tools Rinse tools with water immediately after use. Dried material is difficult to remove.
Drainage and protection boards for building components in contact with the ground The waterproofing must be protected against weathering influences and mechanical damage using suitable protective measures in accordance with DIN 18533. 1. The waterproofing must be totally dry. 2. Suitable protection and drainage boards can be fixed in place with COMBIDIC1K/-S in batches. 3. Perimeter insulation must cover the whole area and be butt jointed with COMBIDIC-2K-CLASSIC or COMBIDIC-2KPREMIUM. 4. Drainage is carried out in accordance with the specifications of DIN 4095.
Storage conditions Storage Store in a frost-free, cool and dry place. At min. 5 - 40 °C for 12 months in the original canister. Promptly use opened container.
Disposal Product residues can be disposed of in accordance with disposal code AVV 17 03 02.
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 4/6
Technical data sheet COMBIDIC®-2K-CLASSIC Notes Protect surfaces that are not to be treated from the effects of COMBIDIC®-2K-CLASSIC! Negative water pressure cannot be absorbed by bituminous waterproofing. It is necessary to apply waterproofing with AQUAFIN®-1K beforehand in the areas in which this can be expected. Do not apply during rain or with air / substrate temperatures below +5 °C. Protect masonry work tops and open window parapets against water penetration. The load case-specific minimum film thickness must not be undershot at any point at the time of acceptance! The required wet film thickness must not exceed 100% at any point. Protect COMBIDIC®-2K-CLASSIC from weathering influences such as rain, frost, strong solar radiation, etc. until totally dry!
Observe applicable safety data sheet! GISCODE: BBP10 Explanations Conformity / Declaration / Verification
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 5/6
Technical data sheet COMBIDIC®-2K-CLASSIC Impact classes and typical applications in accordance with DIN 18533
The rights of the buyer with regard to the quality of our materials are based on our terms and conditions of sale and delivery. Our technical advice team will be happy to advise you in the case of requirements that exceed the scope of the application described here. In order to be binding, a legally binding written confirmation is required. The product description does not release the user from a duty of care. Lay a test area in the event of uncertainty. This version becomes invalid in the event of a new version being issued.
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 6/6